Modular code-compliant power. Connect up to six of our power units together to create a system of power for training spaces, workstations or flexible spaces.
Choose in surface or on surface. Pick the option that best fits your space: in surface or on surface. On surface units can be mounted under or above table surfaces. In surface units include a bezel that hides the mounting screws for a cleaner look.
Easy installation. On surface units can be mounted using clamp (for a damage-free install) or can be installed using wood screws. Installation for in surface units is a snap: Simply cut the opening, insert the unit, tighten the clamps, snap on the bezel a
UL Spill Water Compliant. Passed UL 962A spill water test requirements so it can be used in a horizontal surface, such as a tabletop.
FCC Compliance. This device complies with part 15 of the FCC Rules.
The MDEA3-WH is a Wiremold ModPower End Unit, On Surface, White.
Modular code-compliant power. Connect up to six of our power units together to create a system of power for training spaces, workstations or flexible spaces.
Choose in surface or on surface. Pick the option that best fits your space: in surface or on surface. On surface units can be mounted under or above table surfaces. In surface units include a bezel that hides the mounting screws for a cleaner look.
Easy installation. On surface units can be mounted using clamp (for a damage-free install) or can be installed using wood screws. Installation for in surface units is a snap: Simply cut the opening, insert the unit, tighten the clamps, snap on the bezel a
UL Spill Water Compliant. Passed UL 962A spill water test requirements so it can be used in a horizontal surface, such as a tabletop.
FCC Compliance. This device complies with part 15 of the FCC Rules.
Circuit breaker. You will notice that our units (primary, middle and end) all utilize a circuit breaker. UL962A Supplement SD requires that all furniture power distribution units for portable (moveable) workspace tables contain supplementary overcurrent p
Tamper resistant receptacles. Models have three tamper resistant receptacles to keep little fingers away from danger.
We are open and operating as we are considered an Essential Service under Telecommunications Systems here in the state of California. We are committed to providing our customers with the respect they and their customers deserve by adhering to the safest hygiene protocols and/or mandates published by the CDC as well as other nationally recognized Public Health institutions in order to protect them and our workers on all worksites. AV Structural will be providing all onsite staff with ample and proper Personal Protective Equipment (PPE).